General-technologies FF310 Fault Finder for Electrical Wiring Open / Sh Manuel d'utilisateur Page 8

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 9
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 7
Page 12
15 - CT8002 Professional Circuit Tester
Instructions
1- Hold tester by metal barrel and place free
hand on bare (grounded) metal part of
the vehicle.
2- Place tester point into connector or wire
(pierce insulation if necessary).
3- Tester will light, buzz and vibrate when a
positive voltage is detected.
V-Groove Protector Tip uses:
1- Always insert the V-Groove protector tip on the tester point before carrying or storing
the unit, as this may avoid injuries.
2- Use the V-grove protector tip when piercing wires to prevent the tester point from
side-slipping on the wire and causing injuries or damage.
3- The protector tip may be removed for testing in hard to reach places inside connectors,
sockets, etc.
Replacing the Batteries:
The batteries supplied with the tester will provide years of service under normal use.
When the sound and light starts to fade, remove the screw and pull out the plastic pointer
assembly. Extract the batteries and insert new ones “type Duracell MN9100” or equivalent,
observing the polarity (negative side goes in rst). Insert the tester the point assembly,
then align the holes and replace the screw.
16 - CT6100 Fuse Socket Connectors
The CT6100 fuse socket connectors are designed to facilitate in the connection of test
leads of the FF310 to the circuit under test through the fuse box, and can also be used
for all other situations when access to the fuse socket connections are required. These
connectors are supplied in three sizes: Mini, ATO and Maxi.
How to use the CT6100 connectors
1- Choose the connector (Mini, ATO or Maxi) that
matches the fuse socket where the connection
are required.
2- Remove the power to the circuit.
3- In se rt f us e co n ne ct or i nt o th e so ck et
(see gure).
4- Connect test leads to the connectors tabs of the
fuse socket connector.
17 - Care of the Unit
The FaultFinder is a precision instrument and should be treated as such. Damage caused
by mistreatment is not covered by the warranty.
Keep the units in their carrying case when not in use and do not subject to dampness or
severe heat or cold. Do not use the units in the rain, if they should accidentally get wet.
Dry off with a clean paper towel before storing away.
Protect the units from contact with any solvents. Never clean with a solvent or petroleum
based medium such as gasoline, as these chemicals may attack the plastic parts and
cause permanent damage. Never use an abrasive cleaner. Cleaning should be limited
to wiping with a clean damp paper towel with a small amount of soap if required. Dry the
units thoroughly after any cleaning.
The unit is a sealed instrument and contains no user serviceable parts other than the
battery which can be replaced by opening the drawer on the back of the units. Opening
other parts of the units will void the warranty.
16 - Warranty
With the exception of the batteries, your FaultFinder is warranted against defects of
material or workmanship which develop within a period of one (1) year following the
date of purchase by the original owner. Proof of date of purchase will be required when
applying for repair or replacement under guarantee. For this reason, we strongly suggest
that you keep your sales receipt safely in your FaultFinder storage case.
In the event a aw develops in the FaultFinder, please return it to your dealer who will
arrange repair or replacement. The manufacturer will either repair or replace the tool
(at the manufacturer’s option) free of charge providing the FaultFinder is still under
warranty. If the warranty has expired, there will be a repair charge payable to your dealer
when you pick up the unit. When a unit has been repaired or replaced under warranty, the
replacement unit will continue the warranty period of the original unit for six (6) months
after the date of replacement or until the original warranty expires, whichever is the longest
period. This warranty shall not apply to any defect, failure or damage caused by improper
use or inadequate maintenance or care.
The manufacturer shall not be obligated to provide service under this warranty or to
repair damage resulting from attempts by unauthorized persons to repair or service the
FaultFinder, other than to replace the battery; or to repair damage resulting from improper use.
Specifically if there is evidence of an attempt to open the FaultFinder the
warranty is void.
Any implied warranties arising out of the sale of the FaultFinder including but not limited
to implied warranties of merchantability and tness for a particular purpose are limited in
duration to the above one (1) year period, the manufacturer shall not be liable for loss of
use of the FaultFinder or other incidental damages, expenses or economic loss. Some
Jurisdictions do not allow limitations on how long implied warranties last or the exclusion or
limitation of incidental or consequential damages, so the above may not apply to you.